Open the lid of the iSIC enclosure. Remove both black fuses located to the left of the green digital terminal strip by pressing down on the holder cap and turning it counterclockwise. Wait 10 seconds. Re-install the Battery fuse followed by the External fuse to re-apply power to the system. A green LED visible […]
Articles Tagged: Legacy
Direct iSIC Resource Library
How To FAQ
X2-SDL Cycle Power
Performing a power cycle on an SDL data logger such as the X2-SDL is often useful for troubleshooting purposes. To cycle power on an SDL: Locate the white battery lid at the top of the SDL. Rotate the cap counter-clockwise to remove it. Note: Due to the double O-ring lid seal, this will take significant […]
Send iChart Data Files
During diagnostics it is often necessary for the NexSens Technical Support Specialist to have the raw data information. 1. Open iChart. 2. Click Help | Open Users Folder. 3. Click on the folder named <ProjectName>.Data. 4. Select the year that includes the data in question. 5. Right click on the month that includes the data in question. […]
Send an iChart Project File
During most troubleshooting procedures it is helpful for NexSens to have a copy of the iChart (.icr) file from which the user is working. This allows the technical support specialist to evaluate the current project setup, run tests, and make suggestions for changes. 1. Select Help | Open Users Folder from the iChart menu. 2. Locate […]
iChart Desktop Software – How To
Adjust Communication Timings Adjust Interrogation Schedule Adjust Logger RTC Clock Sync Schedule Check Sensor Parameter Readings Using SDI-12 Install iChart Program an iSIC Data Logger Register iChart Restore project file backup Send a project file for review Send log files for review Send raw data files for review Transfer iChart to a new PC Update […]
iChart Resource Library
How To FAQ
Update Firmware on an RV50 Cellular Modem
Download the Latest ALEOS and Radio Module Firmware Navigate to Sierra Wireless’ RV50 firmware updates page here. For standard RV50 modems, click the ALEOS X.x.x link under the North America heading to download the ALEOS firmware update. For RV50X modems, select the associated ALEOS download under the RV50X heading. For International models of […]
Configure RV50 Modem Settings
All cellular modems that are used with a NexSens iSIC data logger must be configured with the proper settings to communicate and transmit data. While NexSens generally makes the required changes prior to shipping the modem, it may become necessary for a user to verify or change a setting. This can be accomplished by connecting […]
3100 iSIC Data Logger – FAQ
What are the cell account requirements for an iSIC data logger? What do the LED lights indicate on the RV50 cell modem? How to cycle power in the iSIC data logger?