Data Logger Accessories
Mounting, power, communication and more
-
-->
NexSens A01 8.5 A-Hr Battery
The A01 12VDC 8.5 A-Hr battery is included standard with iSIC Data Loggers, SP32 solar power packs, and CB-A01-2 battery harnesses.
-
-->
NexSens A04 6 A-Hr Battery
These high capacity, SLA (sealed lead-acid) batteries fit securely in NexSens SP6, SP8, SP10, SP12, SP13, and SP15 Solar Power Packs.
-
-->
NexSens A05 28 A-Hr Battery
The A05 12VDC 28 A-Hr battery is included standard with CB-A05-X battery harnesses used in CB-Series data buoys.
-
-->
NexSens A71 Desiccant Kit
The A71 desiccant drying agent is designed to absorb moisture inside an iSIC data logger. Included with the purchase of an iSIC data logger.
-
-->
NexSens A73 Triangle Key
The A73 Triangle Key is used to access AVSS Stainless Steel Enclosures.
-
-->
NexSens G2-RAIN Battery Pack
G2 Series Lithium Thionyl Chloride battery pack (2 D-Cells with built-in capacitor and protection)
-
-->
NexSens Gas Discharge Lightning Arrester
Lightning arresters are designed to protect radio, cellular and satellite equipment from harmful static electricity and lightning induced surges.
-
-->
NexSens High Gain Cellular Antenna
The A49 high gain cellular antenna is an excellent choice for remote communication via GPRS/GSM, EDGE, or CDMA cellular transmission.
-
-->
NexSens Iridium Satellite Antenna
The NexSens A42 Iridium Antenna offers improved performance with X2 data loggers when the standard whip antenna is not sufficient.
-
-->
NexSens MAST Aluminum Mounting Pole
The MAST is a 2" NPT aluminum pipe assembly designed for mounting an X2 data logger and SP-Series solar power pack for quick deployment.
-
-->
NexSens MC 2-Way Sensor Splitter
The 2-way wet-mate sensor splitter expands the number of sensor ports on an X2-CBMC or X2-SDLMC data logger.
-
-->
NexSens MCIL Female Cable Connectorization
The NexSens MCIL female cable connectorization service includes assembly, test, and setup of user-supplied sensor cables for communication to X2-SDLMC and X2-CBMC data loggers.
-
-->
NexSens PM2 Data Logger Mounting Kit
The NexSens PM2 is a specially designed X2 mounting bracket. The PM2 holds the X2 to a pole or wall and allows for easy connection and removal.
-
-->
NexSens RF Extension Cables
NexSens RF extension cables allow users to connect external antennas to X2/V2 cellular, satellite, and radio telemetry systems.
-
-->
NexSens SBP500 Submersible Battery Pack
The SBP500 Submersible Battery Pack accommodates (16) user-replaceable D-cell alkaline batteries in a completely submersible enclosure for power to underwater sensors or data loggers.
-
-->
NexSens SP-Series Solar Power Packs
The SP-Series Solar Power Packs feature a solar panel, regulator, and battery housed in a weather tight enclosure.
-
-->
NexSens UW Plug to Flying Lead Cables
The UW plug to flying lead cable is used to wire external sensors to the X-Series data loggers.
-
-->
NexSens UW Receptacle to Flying Lead Cables
The UW receptacle to flying lead cable is used for wiring sensors with integrated UW plug connectors to a data logger terminal strip.
-
-->
NexSens UW6 2-Way Power Splitter
The 2-way power splitter is used to connect or split multiple DC power sources on the X2 family of data loggers.
-
-->
NexSens UW6 AC Power Adapter
A power adapter used to power NexSens X2 or G2-Series systems from a wall outlet for continuous unattended monitoring applications.
-
-->
NexSens UW6 Battery Backup
The UW6-BB battery backup provides auxiliary power to X2 and G2-Series systems when primary AC power is disrupted.
-
-->
NexSens UW6 Extension Cables
NexSens UW6 extension cables are used to extend the distance between X2 data loggers and power sources such as the SP-Series Solar Power Packs and SBP500 Submersible Battery Packs.
-
-->
NexSens UW6 Plug to Flying Lead Cables
The UW plug to flying lead cable is used to wire external power and/or communications to the X-Series data loggers.
-
-->
NexSens UW6 Plug to UW Plug Cables
The UW6 Plug to UW Plug Cable provides a mating connection between the SBP500 submersible battery pack and the X2 line of data loggers.
-
-->
NexSens UW6 Power Bulkhead Connector Assembly
The UW6 power bulkhead connector assembly allows customers to integrate SP-Series solar power packs into 3rd party enclosures.
-
-->
NexSens UW6 Power Plug Connector Cap
Power plug connector caps are used to provide a waterproof seal on cables with UW6 plug connectors when servicing buoys and X2 data loggers.
-
-->
NexSens UW6 Power Port Plug
Power port plugs can be used to provide a watertight seal around an unused data logger power port during deployments.
-
-->
NexSens UW6 Receptacle to Flying Lead Cables
The UW6 receptacle to flying lead cable allows users to wire SP-Series solar power packs into external electronics with 12VDC power requirements.
-
-->
NexSens X2 Direct Connect USB PC Cable
The UW6 to USB cable is designed to allow direct connection from a PC to an X2 data logger for advanced setup or diagnostics.
-
-->
NexSens X2-SDL Instrument Cage Mount
The NexSens X2-SDL instrument cage mount is designed to securely attach X2-SDL submersible data loggers and SBP500 submersible battery packs to an instrument cage in buoy-based applications.
-
-->
NexSens X2-SDL Submersible Antenna Cap
The X2-SDL submersible antenna cap provides extra ingress protection for telemetry units when submerged for extended periods.