X-Series Logger Diagnostic Readings

All X-Series data loggers have an internal set of sensors that measure important system health factors, which are called meta parameters or diagnostic readings. The X2 logger collects a total of 12 meta parameters and the X3 logger collects a total of 7 meta parameters. X-Series Meta Parameter Descriptions Processor Power (X2 Only) – The […]

Read More

Data Buoy Storage Requirements

The following buoy storage requirements are required when storing a CB-Series data buoy with an X2-CB data logger: Storage Requirements Store the buoy in a dry environment that is kept above freezing. A climate-controlled location may be necessary. Extremely cold temperatures can negatively impact the performance of the batteries. Cold or excessively fluctuating storage temperatures […]

Read More

X2-SDL Storage Requirements

The following practices should be carried out when placing an X2-SDL data logger in storage for an extended period of time: Remove all D-Cell batteries inside the data logger. The battery installation procedure can be referenced for removal guidance. Batteries left inside may leak and corrode the internal compartment of the logger. Any X2-SDL left powered […]

Read More

‘Buffer size does not match’ error

The ‘buffer size does not match’ error is output in the diagnostic window of iChart during an attempted data upload when the programmed configuration of the iSIC data logger does not match the configuration of the selected logger in the iChart project.   This typically occurs when: A configuration change has been made to the […]

Read More

Program an iSIC Data Logger

The Setup Device Wizard facilitates the creation and management of an iChart project file. Through the wizard, users can program iSIC data loggers with the appropriate sensor configuration. To access this within an iChart project, navigate to Project | Setup Device Wizard Step 1 – Site Setup Create and name site(s) for the data loggers […]

Read More

‘Unexpected File Format’ Error

An ‘unexpected file format’ error in iChart indicates that the project (.icr) file attempting to be opened has an incompatibility with the current version of the software: The .icr file was created with a newer version of iChart than the version of the software trying to open it (most common). The properties of the .icr […]

Read More

How To Update the NexSens iChart Software

Navigate to Help | Check for Updates within iChart. If an update is available – a confirmation prompt will appear requesting permission to proceed.   Click Yes to begin downloading the update. When the upgrade is finished downloading, click OK and restart iChart as requested.   The installation process will begin when iChart restarts. If […]

Read More

Adjust Communication Timings

When using a third party USB to serial adapter it may be necessary to alter the communication timing between iChart and the data logger. 1. Open iChart with the current project. 2. Hold down CTRL, ALT, and T to bring up the Communication Timing menu. 3. Select NexSens DN Sensors from the Device field. 4. […]

Read More