Set Up a NexSens Radio Network

Each XBEE radio module that ships with a NexSens radio X2 has a unique identifier. Both the base and field nodes use this identifier to establish connections throughout the radio network. All field radios in the network must have the identifier information for the base station as a destination for their logged data. An RF […]

Read More

Setup Iridium Logger Through CONNECT

Satellite/Iridium transmission is more expensive than other traditional forms of communication (e.g., cellular, radio, Wi-Fi). Therefore, it is imperative that the end-user only transmit the most useful diagnostic and sensor parameters. The CONNECT software can set these parameters and their log/transmission interval before the data logger transfers data to the web. Thus, outlining the proper […]

Read More

Read/Start an X2 Sensor Measurement

A real-time X2 sensor measurement may be viewed or started using the data acquisition tab (DAQ) in the CONNECT software. This is often a useful tool to use during system configuration or troubleshooting. Remember that many sensors may take several seconds or minutes to complete their measurement, so allow ample time for the measurement cycle […]

Read More

Iridium Transmission Delay

Compared to data loggers utilizing cellular, radio, or Wi-Fi telemetry, Iridium transmission systems have an additional step in the data upload process which may cause a delay in the time it takes from the logger recording a measurement to data being posted on WQData LIVE. Data messages transmitted from the logger’s satellite modem are first […]

Read More

SD Card Utility

The X2 SD Card Utility in CONNECT allows users to perform the following actions without needing to physically access the micro-SD card inside the X2 data logger: Send a file to the SD Card Transfer a file from the SD Card to the PC Delete a file off of the SD Card   Access X2 […]

Read More

X2 Diagnostics

The X2 Diagnostics utility in CONNECT software enables users to perform the following functions: Read the logger’s diagnostic sensor suite Toggle sensor port power on/off Enable/disable on-board Wi-Fi   Access X2 Diagnostic Utility Connect the X2 logger to a PC and launch the CONNECT software. Test connection by reading the RTC clock of the logger […]

Read More

Update Firmware

Firmware for the X2 data logger is updated periodically to account for new features, more environmental sensors, and any bug fixes. Upon request, a technical support technician at NexSens Technology will provide a ‘.bin’ file containing the latest firmware update. This file must then be transferred to the proper folder for CONNECT to complete the […]

Read More

Access CONNECT Program Files

On occasion it may be necessary to manually place program files provided by NexSens Technology into the CONNECT software folder. Select the DATA tab within CONNECT.   Click the Open Data Folder button to view the CONNECT | Data folder directory.   In the Windows File Explorer navigation bar, click CONNECT (highlighted above) to navigate to the parent […]

Read More

X-Series Logger Storage Requirements

The following practices should be carried out when storing an X-Series data logger for an extended period of time: Disconnect the solar tower cable, SP-series solar power pack, or UW6-PW AC power adapter cable from the center 6-pin port on the data logger. Cap the 6-pin port with the blank plug included during shipment. Disconnect […]

Read More