Data Export Predefined Tag List

The following list contains descriptions for the Predefined Tag names under the data export tool using the GLOSXML or NDBCXML format. Name Description atmp1 Air temperature (deg. C) baro1 Air pressure adjusted to sea level, primary sensor (hPa) baro2 Air pressure adjusted to sea level, secondary sensor dewpt1 Dew point temperature (deg. C) do YSI […]

Read More

Temporarily Set iSIC Logger Secondary Baud Rate

The iChart software contains a terminal emulator used to communicate with sensors via serial output. Follow the process below to temporarily change the terminal, or secondary, baud rate to communicate with a wide range of sensors through an iSIC data logger. WARNING: This procedure should only be conducted while in direct connection with the iSIC data […]

Read More

Enable Datalog on Turner Designs Sensors

The following information describes the process for enabling data output on a Turner C6 sensor. Enabling data output is required for communication with any NexSens data loggers.   Connect to the C6 sensor using the C-Soft software. Follow the information below, acquired from Section 3.5 of the Turner Designs C6 Multi-Sensor Platform User Guide.   […]

Read More
UW-FWP,

Check Resistance on a UW-FWP

If a sensor wired to a UW-FWP does not communicate with a data logger or begins to display intermittent readings, it is recommended to ohm out the pins on the connector. As communication between water quality sensors and data loggers requires low resistance for proper transmission, ensuring the UW-FWP resistance is within NexSens specifications will […]

Read More

TS210/T-Node FR Sensor Drift

As with all electronics, sensor drift may occur in the NexSens TS210/T-Node FR temperature sensors over time due to aging and exposure to environmental conditions. This drift has been quantified in the laboratory, as shown in the chart below. Temperature is recorded based on the electrical resistance (ohms) through the sensor’s titanium thermistor. As the […]

Read More

Public Portal Data API

The Public Portal Data API is designed to pull data from the WQData LIVE My SQL database and directly feed that to the WQDataLIVE public portal display. Learn how to enable and configure the public portal for your project by reading the Configure Public Portal article. Limitations The following limitations occur with this API: WQDataLIVE […]

Read More

Generate Generic NMEA 0183 Script

NMEA 0138 sensors not already listed in the X2 sensor script library can be configured to communicate with the X2 by generating a generic NMEA 0138 script. Connect the X2 logger to a PC and launch the CONNECT software. Test connection by reading the RTC clock of the logger in the CONFIG tab. On the […]

Read More

Which X2-Configured Airmar Parameters Require a Satellite Connection?

The following Airmar WX-Series parameters require a satellite connection to record measurements on the X2 data logger. (Read the Airmar X2 Integration Guide article to learn about the Airmar WX-Series parameters available for the X2.)   NMEA 0183 Message Description X2 Parameters $GPGGA NMEA 0183 standard GPS Fix Data UTC Time (hhmmss) Latitude (Degree) Longitude […]

Read More

Which Airmar Parameters Require a Humidity Module?

The following Airmar WX-Series parameters, that are compatible with an X2 data logger, require a humidity module to record measurements. (Humidity modules may be purchased on the Fondriest Environmental website)   NMEA 0183 Message Description X2 Parameters $WIMDA NMEA 0183 Standard Meteorological Composite (Wind parameters with respect to north) Relative Humidity (%) Dewpoint (C)   […]

Read More
Airmar 200WX WeatherStation.

Airmar 200WX NMEA Output Messages

The Airmar WX-Series Weather Station contains multiple wind speed and direction parameters depending on the preferred reference point at the site location and the motion of the station on its platform. NMEA 0183 output messages correlate as follows: NMEA 0183 Message Description X2 Parameters $WIMDA* NMEA 0183 Standard Meteorological Composite (Wind parameters with respect to […]