Changing Data Logger Transmission Frequency

    The Timed Transmission setting in the Remote Device Configuration menu determines how often the data logger will power-up its telemetry to contact the WQData LIVE Data Center. Each transmission the data logger will : (1) Upload all new logged data and (2) Process all configuration changes active in the Command Queue. Access the Remote Device Configuration […]

    Read More

    Changing Individual Sensor Logging Intervals

    Access the Remote Device Configuration menu for the data logger on the WQData LIVE Project. Navigate to the Timed Data Acquisition section of the menu. Expand the listing for each sensor and enter in the desired data collection interval. Note that increasing the logging frequencies of sensors will increase power demand for the system. Certain sensors […]

    Read More

    Configuring Parameter Offsets

    Access the Remote Device Configuration menu for the data logger on the WQData LIVE Project. Navigate to the Parameter Settings section of the menu. Expand the sensor list to reveal the parameter for which the offset is to be applied. Enter the desired offsets into the A, B, C settings fields below the parameter. These […]

    Read More

    Configure a Control Output on an iSIC-V2

    Materials Required iSIC-V2 Firmware V8.02.14 or greater PC with iChart Software V6.20.021 or newer Serial Cable with USB Adapter Process Launch iChart and open the current project (.icr ) file  for the system. Right click on the logger in the Navigation Panel, select Property.  Connect a serial cable to the iSIC-V2 logger and select the […]

    Read More

    Solar Radiation

    Solar radiation is radiant (electromagnetic) energy measured using a photosynthetically active radiation (PAR) sensors that measure upwelling and downwelling solar radiation.

    Read More

    Kipp & Zonen NR Lite2 CB-650 Buoy Installation

    This article demonstrates how to affix the NR Lite2 terrestrial PAR sensor to a CB-650, 950, or 1250 buoy using the manufacturer’s CMB 1 mounting bracket. Required Tools 10mm socket 13mm wrench 13mm socket Level CMB1 Mount Hardware (1) CMB 1 Mounting brace (3) V-blocks (4ea) M8 flat washer, lock washer, nut (2) M8x99x71 U-bolts (4ea) […]

    Read More

    NexSens Underwater PAR Arm Installation

    This article demonstrates how to mount a LI-COR 192 PAR sensor onto a Unistrut arm for small and large instrument cages. Required Tools  Socket/combination wrench sets: 3/8″, 7/16″, 9/16″ Size 25 metric Allen wrench Flat head screwdriver Phillips head screwdriver Included Components All Cage Sizes Mounting Block HydroWiper to Mounting Block– (7) 10-32x 1-3/8 pan […]

    Read More

    GMX 600- CB-Series Buoy Mount Installation

    This article demonstrates how to mount a GMX 600 weather station onto a buoy solar tower. Tools -Phillips head screwdriver -Zip Ties (recommended) Included Materials -(3) 10-32 X 5/8″ Pan head screws -(3) #10 lockwashers -(3) #10 flat washers Installation Route the GMX 600 cable through the top of the buoy solar tower.   Attach […]

    Read More

    G2-RAIN External Power Adapter Cable Installation

    Tools Required 3/16″ hex key 5/16″ hex key small adjustable wrench Small Flat head screwdriver Tweezers (recommended) Procedure 1) Remove the G2-Rain from its mounting pole and invert. 2) Use a small flat head screwdriver and turn the power switch counter-clockwise to remove internal power.   3) Use a 5/16″ hex key to remove the […]

    Read More

    WQData LIVE Project Creation & Site Setup

    Step 4- Project Creation and Site Addition If the Quick Device Setup was not utilized to claim the device, create a new project. Navigate to the Project List page If adding a new project to an existing account, click on PROJECTS under the top menu drop down Click the Create New Project panel Fill out the form with the following […]