Why is a T-Node FR Not Detecting?

The NexSens T-Node FR User Guide outlines the required process for integrating a T-Node FR temperature sensor or string with a NexSens X-Series data logger. If one or multiple nodes along the string fail to detect after following the guide, below is a list of common reasons. Issues During T-Node FR Detection Issue #1: Two […]

Read More

T-Node FR/TS210 Register Information

Modbus-RTU Register Information The NexSens T-Node FR/TS210 Temperature string outputs values as 32-bit IEEE 754 floating point numbers in big-endean format. To convert from a hexadecimal value to a decimal value, use an IEEE-754 Floating Point Converter. Insert the hex output (e.g., 0x41af381d) into the “Hexadecimal Representation,” and the “Decimal Representation”, the temperature in degrees […]

Read More
In-Situ RDO Blue.

Why is an In-Situ RDO Sensor Not Detecting?

The In-Situ RDO-Pro/Blue X-Series Integration Guide outlines the required process for integrating In-Situ RDO Sensors with NexSens X-Series data loggers. If an In-Situ RDO Sensor fails to detect after following the guide, below is a list of common reasons. Issues During Detection Issue #1: The In-Situ settings were not saved properly within the software. Explanation: […]

Read More

Prevent Pressure Build-Up in CB-Series Data Wells

Due to temperature and barometric pressure changes, or in some cases, battery off-gassing, buoys with sealed compartments, including battery and data wells, can build up pressure or establish a vacuum over time. To reduce these effects, NexSens CB-Series buoy lids are equipped with either a membrane vent or, for rough water applications, a 5 PSI […]

Read More
SonTek SL-series Doppler Current Meters.

Why is the SonTek Not Gathering Readings?

The SonTek-SL Current Meter X-Series Integration Guide outlines the required process for integrating SonTek-SL Series of Side-Looking Doppler Current Meters with NexSens X-Series data loggers. If a SonTek meter is not providing values after following the guide, below is a list of common reasons. Issues with Gathering SonTek Readings Issue #1: The SonTek is connected […]

Read More
NexSens UW Plug to Flying Lead Cable.

SonTek Flying Lead Wiring into A50 Junction Box

In the event of using the flying lead wires from the SonTek-SL Series current meters to wire into a NexSens A50 junction box, below is a wiring diagram for the connections between the SonTek cable and a NexSens plug to flying lead cable (UW-FLx). SonTek SL-Series Signal SonTek SL-Series Wire Color NexSens UW-FLx Cable Wire […]

Read More
Sontek SL-series current meter.

NexSens Plug Connections for SonTek Current Meters

If users are connecting a SonTek current meter to an external device that is not an X-series data logger via a NexSens UW8 connector, use the pinout chart below.   NexSens UW8 Plug Pin Number Signal 1 RS232 Tx* 2 Ground 3 RS232 Rx* 5 12V+ 6 SDI-12 *RS232 signals are used to communicate with […]

Read More
YSI EXO3 multiparameter sonde.

Why is an EXO Sonde Not Detecting?

The YSI EXO Water Quality Sondes X-Series Integration Guide outlines the required process for integrating a YSI EXO sonde with a NexSens X-Series data logger. If an EXO sonde fails to detect after following the guide, below is a list of common reasons. Issues During Sonde Detection Issue #1: The EXO deployment template was not […]

Read More