Overview The Seametrics CT2X is a conductivity and temperature sensor with built-in data logging. Incorporating a 4-pole epoxy and graphite electrode cell, it is extremely durable and resistant to data interferences — making it excellent for use in rugged field conditions.
Extensive Control The CT2X also comes with Seametrics' powerful, easy-to-use Aqua4Plus and Aqua4Plus Lite software, affording the user extensive control, including real-time monitoring, flexible programming, and versatile data display options.
Benefits
Measures conductivity, total dissolved solids, and temperature
Ranges from 10 microsiemens/cm to 100,000 microsiemens/cm
Pressure and level option available
In-field calibration utilities
Narrow 0.75″ diameter, 12.5″ or 16″ length (depending on version)
Linear and nLFn temperature compensation
Up to 349,000 records in non-volatile memory
316 stainless steel, fluoropolymer, and PTFE construction (titanium optional)
Digital industry standard RS485 interface
Available with a variety of cable options—including polyethylene, polyurethane, and FEP Teflon
Modbus and SDI-12 protocols available
Easy export to spreadsheets and databases
Parts
Image
Part#
Product Description
Quote
2F21510
CT2X conductivity & temperature logger with stainless steel housing, includes cableless top cap
2F21552
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 30 PSIA range, includes cableless top cap
2F21554
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 50 PSIA range, includes cableless top cap
2F21556
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 100 PSIA range, includes cableless top cap
2F21558
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 300 PSIA range, includes cableless top cap
2F22510
CT2X conductivity & temperature logger with titanium housing, includes cableless top cap
2F22552
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 30 PSIA range, includes cableless top cap
2F22554
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 50 PSIA range, includes cableless top cap
2F22556
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 100 PSIA range, includes cableless top cap
2F22558
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 300 PSIA range, includes cableless top cap
2F31510
CT2X conductivity & temperature logger with stainless steel housing, requires cable
2F31524
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 5 PSIG range, requires cable
2F31526
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 15 PSIG range, requires cable
2F31528
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 30 PSIG range, requires cable
2F31530
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 50 PSIG range, requires cable
2F31532
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 100 PSIG range, requires cable
2F31534
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 300 PSIG range, requires cable
2F31552
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 30 PSIA range, requires cable
2F31554
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 50 PSIA range, requires cable
2F31556
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 100 PSIA range, requires cable
2F31558
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 300 PSIA range, requires cable
2F32510
CT2X conductivity & temperature logger with titanium housing, requires cable
2F32524
CT2X vented water level, conductivity & temperature logger with titanium housing, 5 PSIG range, requires cable
2F32526
CT2X vented water level, conductivity & temperature logger with titanium housing, 15 PSIG range, requires cable
2F32528
CT2X vented water level, conductivity & temperature logger with titanium housing, 30 PSIG range, requires cable
2F32530
CT2X vented water level, conductivity & temperature logger with titanium housing, 50 PSIG range, requires cable
2F32532
CT2X vented water level, conductivity & temperature logger with titanium housing, 100 PSIG range, requires cable
2F32534
CT2X vented water level, conductivity & temperature logger with titanium housing, 300 PSIG range, requires cable
2F32552
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 30 PSIA range, requires cable
2F32554
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 50 PSIA range, requires cable
2F32556
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 100 PSIA range, requires cable
2F32558
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 300 PSIA range, requires cable
2F41510
CT2X conductivity & temperature logger with stainless steel housing, requires cable & external power
2F41524
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 5 PSIG range, requires cable & external power
2F41526
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 15 PSIG range, requires cable & external power
2F41528
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 30 PSIG range, requires cable & external power
2F41530
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 50 PSIG range, requires cable & external power
2F41532
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 100 PSIG range, requires cable & external power
2F41534
CT2X vented water level, conductivity & temperature logger with stainless steel housing, 300 PSIG range, requires cable & external power
2F41552
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 30 PSIA range, requires cable & external power
2F41554
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 50 PSIA range, requires cable & external power
2F41556
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 100 PSIA range, requires cable & external power
2F41558
CT2X non-vented water level, conductivity & temperature logger with stainless steel housing, 300 PSIA range, requires cable & external power
2F42510
CT2X conductivity & temperature logger with titanium housing, requires cable & external power
2F42524
CT2X vented water level, conductivity & temperature logger with titanium housing, 5 PSIG range, requires cable & external power
2F42526
CT2X vented water level, conductivity & temperature logger with titanium housing, 15 PSIG range, requires cable & external power
2F42528
CT2X vented water level, conductivity & temperature logger with titanium housing, 30 PSIG range, requires cable & external power
2F42530
CT2X vented water level, conductivity & temperature logger with titanium housing, 50 PSIG range, requires cable & external power
2F42532
CT2X vented water level, conductivity & temperature logger with titanium housing, 100 PSIG range, requires cable & external power
2F42534
CT2X vented water level, conductivity & temperature logger with titanium housing, 300 PSIG range, requires cable & external power
2F42552
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 30 PSIA range, requires cable & external power
2F42554
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 50 PSIA range, requires cable & external power
2F42556
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 100 PSIA range, requires cable & external power
2F42558
CT2X non-vented water level, conductivity & temperature logger with titanium housing, 300 PSIA range, requires cable & external power