Vented Water Level Specifications

 

SensorVented Pressure Transducer
Measurement Range0 to 5 meters standard; Custom ranges from 1 to 275 meters
Accuracy+/-0.1% Full Scale TEB
Operating Temperature-10 to +80 C
Power Requirements8 to 28 VDC
Outputs0 to 2.5 VDC analog, Modbus RS-485
Body Material316L stainless steel or titanium
Cable TypePolyethylene-jacketed, vented & shielded
Cable Length10, 20 & 30 meters standard; Custom lengths available
Sensor Length109mm (4.29″)
Sensor Diameter21mm (0.825″)

 

Non-vented Water Level Specifications

 

SensorAbsolute pressure transducer
Measurement Range1 to 275 meters
Accuracy+/-0.1% Full Scale TEB
Operating Temperature-10 to +80 C
Compensated Temperature-10 to +80 C
Power Requirements8 to 28 VDC
Outputs0 to 2.5 VDC analog, Modbus RS-485
Body Material316L stainless steel or titanium
Cable TypePolyethylene-jacketed & shielded
Cable Length10, 20 & 30 meters standard; Custom lengths available
Sensor Length109mm (4.29″)
Sensor Diameter21mm (0.825″)

 

REV: 13G26