Sometimes it is desirable to connect a CB-iSIC directly to the PC for configuration, setup, testing, and troubleshooting. This can be accomplished with the included UW-USB-232P-NP cable.

  1. Connect the CB-iSIC to the PC by plugging the USB cable into the CB-iSIC’s COM port. The RTU module will need to be disconnected.
  2. Power the iSIC-CB by connecting the solar panel or a UW-JUMPER to the SOLAR port.
  3. In the iChart Navigation Panel, right-click the data logger (name may vary depending on the communication type) and select Property.
    navpanel

    Figure 1: iChart Navigation Panel

  4. Make note of the current settings including Address and IP/IMEI/COM Port.
  5. Change the Connect Through type to Direct to PC

    comprop

    Figure 2: Data Logger Communication Properties

  6. Confirm the iSIC Address is correct and the correct COM port is selected.
    http://www.nexsens.com/knowledge-base/software/ichart/verifying-isicsdl-com-port.htm
  7. Click Test Connection and confirm that the communication test is successful.
    comtest

    Figure 3: Test Communication

    Once this is confirmed, the device can be used as a direct connect data logger.

    Once all direct setup and testing is done, the iChart file needs to be set back to using telemetry communication.

  8. In the iChart Navigation Panel, right-click the data logger (name may vary depending on the communication type) and select Property.
    navpanel

    Figure 4: iChart Navigation Panel

  9. Change the Connect Through back to the original configuration and confirm all settings are correct based on those recorded above.