The CB-iSIC is outfitted with various ports with different functionality.

UW 8 Pin Numbering

The ports on the iSIC-CB bulkheads are Underwater Receptacles (UW-R) that accommodate Underwater Plug (UW-P) connections from various sensors and communication devices. The mating plug’s signals are mirrored to those of the receptacle. For example, pin 1 on the receptacle mates with pin 8 on the plug.

Pins on UW Plug

Figure 1: Pins on UW 8-Plug

 

Typical SDL500 Port

Figure 2: Pins on UW 8-Receptacle

 

Regardless of whether the UW connector is a plug or receptacle the pins are numbered in the same manner. With the pins on the right and the sockets on the left numbering is done clockwise starting with pin 1 at the 1 o’clock position and ending with pin 8 at the 11 o’clock position.

UW8_Render_Numbered

Figure 3: UW 8 Pin Numbering

 

UW 6 Pin Numbering

The UW 6 port is used for solar power input and also acts as a power switch to disconnect the internal battery. Numbering is done in the same manner as with the UW 8 connector.

UW6_Render_Numbered

Figure 4: UW6 Pin Numbering

UW Pin Signals

Receptacle PinP0P1P2SOLARCOM
1485A485A485ANCH_485A
2485B485B485BNCH_485B
3SDI-12SDI-12SDI-12BAT
(Jumper1)
SDI-12
4BATSW12VSW12VGNDSW12V.RTU
5SW5VSW5VSW5VSOLAR_INKey
6P0.RxP1.RxP2.RxSOLAR_OUT & LOGGER_IN
(Jumper1)
H_232Rx
7GNDGNDGNDN/AGND
8P0.TxP1.TxP2.TxN/AH_232Tx

The Jumper pins must be connected to power the logger from the battery

Leave a Reply

Your email address will not be published. Required fields are marked *

Time limit is exhausted. Please reload CAPTCHA.