AccuStage Reads -99999.992

    A level value of -99999.992m or 328079.974ft is an indicator of no communication between the iSIC data logger and the AccuStage water level sensor. It is possible to resolve this issue. 1. Refer to the AccuStage Manual for wiring and pin numbers. 2. Ensure all wires are in the correct locations according to “Figure 3” in the […]

    Read More

    Calibrating an AccuStage

    To calibrate an AccuStage, make sure that the sensor is wired properly by referring to its Sensor Interface article. Next open iChart software with the current project file and click Advanced | Sensor Interface | AccuStage.     The AccuStage Setup window will appear.     There are different Connection type options available, but calibration […]

    Read More

    AccuStage Deployment and Maintenance

    Installation The AccuStage level sensor can easily be installed in a 1” or larger stilling well or deployment pipe, or can be deployed beneath NexSens data buoys. Additionally, for best level measurements, make sure the AccuStage is installed below the lowest anticipated water level during unattended deployments. For vented sensors, care should be taken to […]

    Read More

    AccuStage Specifications

    Vented Water Level Specifications   Sensor Vented Pressure Transducer Measurement Range 0 to 5 meters standard; Custom ranges from 1 to 275 meters Accuracy +/-0.1% Full Scale TEB Operating Temperature -10 to +80 C Power Requirements 8 to 28 VDC Outputs 0 to 2.5 VDC analog, Modbus RS-485 Body Material 316L stainless steel or titanium […]

    Read More

    AccuStage Overview

    The NexSens AccuStage water level sensor is a completely self-contained pressure transducer. Both water level and temperature readings are available on the RS-485 Modbus output. Additionally, water level is available on the 0-2.5VDC analog output. The AccuStage is available in vented or absolute configurations and is ideally suited for long-term environmental monitoring applications in surface […]

    Read More

    NexSens Accustage

    Instructions for interfacing the NexSens Accustage with a NexSens iSIC data logger: IMPORTANT: Review the manufacturer’s manual for the sensor to ensure that the sensor is properly configured for integration with a third party data logger prior to connecting the device to the iSIC. 1. Route cables and wires through one of the gland fittings installed […]

    Read More

    Warranty & Service

    NexSens Technology, Inc. warrants products against defects in materials or workmanship for a period of 12 months from the date of delivery to the original customer. This warranty is limited to the replacement or repair of such defects, without charge, when the product is returned to NexSens Technology, Inc. Damage due to accidents, misuse, tampering, […]

    Read More